Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Adicionar filtros








Intervalo de ano
1.
Journal of Biomedical Engineering ; (6): 537-543, 2022.
Artigo em Chinês | WPRIM | ID: wpr-939621

RESUMO

Currently, as the key raw material of artificial biological heart valve, bovine pericardium is mainly depend on import and has become a "bottleneck" challenge, greatly limiting the development of domestic biological heart valve. Therefore, the localization of bovine pericardium is extremely urgent. In this study, the pericardium of Sichuan yak was compared with that of Australian cattle in terms of fundamental properties and anti-calcification performance. The results demonstrated that the appearance and thickness of yak pericardium were more advantageous than the Australian one. Sichuan yak pericardium and Australian cattle pericardium had comparable performance in shrinkage temperature, mechanical test and anti-calcification test. This study preliminarily verifies the feasibility of substitution of Australian cattle pericardium by Sichuan yak pericardium and promotes the progression of bovine pericardium localization with data support.


Assuntos
Animais , Bovinos , Austrália , Bioprótese , Próteses Valvulares Cardíacas , Pericárdio
2.
Chinese Journal of Medical Instrumentation ; (6): 448-452, 2020.
Artigo em Chinês | WPRIM | ID: wpr-942760

RESUMO

The purpose of this study was to investigate the NOAEL of the nickel ion and provide with basic data for the biological evaluation of those medical devices containing nickel. Five groups SD rats were repeatedly exposed during 14 d respectively to nickel at first stage doses of 4.9, 3.7, 2.5 mg/(kg.d), and the second stage doses of 1.2, 0.25 mg/(kg.d) by the intravenous route. The results showed that the NOAEL of nickel ion is 0.25 mg/(kg.d) for SD rats, and the result was verified by subchronic systemic toxicity test of nickel alloy. The threshold of toxicological concern (TTC) of nickel is 150 μg/d (based on application of 100-fold uncertainty factor and a body weight of 60 kg)deduced by these data.


Assuntos
Animais , Ratos , Equipamentos e Provisões/efeitos adversos , Níquel/toxicidade , Nível de Efeito Adverso não Observado , Ratos Sprague-Dawley , Medição de Risco
3.
Chinese Journal of Medical Instrumentation ; (6): 212-215, 2015.
Artigo em Chinês | WPRIM | ID: wpr-265661

RESUMO

The purpose of this study was to investigate the cytotoxicity of the nickel ion and provide with basic data for the biological evaluation of those medical devices containing nickel. Seven cell lines were chosen. They were L929, h9c2(2-1), 293[HEK-293], hFOB1.19, THLE-3, H9 and IM-9 respectively. According to the principle of biological evaluation of medical devices, MTT method was chosen to test the cytotoxicity in different concentrations of nickel ion. For each cell line, the relative growth rate (RGR) was obtained and the cytotoxic grade was classified. Besides, IC50 values were calculated. As a result, it was found that the sensitivity was different among all cell lines. H9 was the most sensitive one, while the L929 was the most tolerant one. The concentration which is not above 1.25 mg/L was safe for all seven cell lines, because the cytotoxicity for all cells exposed in this concentration were not higher than grade 1. According to the criteria for medical devices, the concentrations not above 5 mg/L were safe for L929 cells. This result helps us to roughly assess the cytotoxicity and systematic toxicity caused by nickel contained in medical devices.


Assuntos
Humanos , Linhagem Celular , Equipamentos e Provisões , Células HEK293 , Íons , Toxicidade , Níquel , Toxicidade
4.
Chinese Journal of Medical Instrumentation ; (6): 129-131, 2013.
Artigo em Chinês | WPRIM | ID: wpr-264254

RESUMO

The dissolution of nickel from nitinol alloy under different extraction conditions was investigated when biological tests of nitinol medical devices were carried out. It discussed the equivalence of these extraction conditions and found the best extraction conditions. In the experiment, two brands of nitinol were chosen and extracted under different extraction conditions according to GB/T 16886-12. Plasma emission spectrometer was used to analyse the concentration of nickel in extract liquid. The results show that there is no equivalence among these extraction conditions for nitinol materials. And it is suggested that (37 +/- 1) degree C, (72 +/- 2) h could be used as normal extraction condition and (70 +/- 2) degrees C, (24 +/- 2) h as accelerated extraction condition.


Assuntos
Ligas , Química , Materiais Biocompatíveis , Teste de Materiais , Níquel , Química , Temperatura , Titânio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA